CTW1=0, DVWHI0=000, DVWHI1=000, DVWCMD0=000, DVWCMD1=000, CTW0=0, DVWLO1=00, DVWLO0=00
Device Memory Map Write Chip Select Timing Setting Register
CTWW0 | Device 0 single continuous write waiting cycle setting in PCLKA units |
CTW0 | Device 0 single continuous write mode setting 0 (0): Single continuous write mode is disabled for device 0 1 (1): Single continuous write mode is enabled for device 0 |
DVWCMD0 | Device 0 Command execution interval setting 0 (000): 2 clock cycles 1 (001): 5 clock cycles 2 (010): 7 clock cycles 3 (011): 9 clock cycles 4 (100): 11 clock cycles 5 (101): 13 clock cycles 6 (110): 15 clock cycles 7 (111): 17 clock cycles |
DVWHI0 | Device 0 select signal pull-up timing setting 0 (000): 1.5 clock cycles (DOPI mode) 2 clock cycles (Other mode) 1 (001): 2.5 clock cycles (DOPI mode) 3 clock cycles (Other mode) 2 (010): 3.5 clock cycles (DOPI mode) 4 clock cycles (Other mode) 3 (011): 4.5 clock cycles (DOPI mode) 5 clock cycles (Other mode) 4 (100): 5.5 clock cycles (DOPI mode) 6 clock cycles (Other mode) 5 (101): 6.5 clock cycles (DOPI mode) 7 clock cycles (Other mode) 6 (110): 7.5 clock cycles (DOPI mode) 8 clock cycles (Other mode) 7 (111): 8.5 clock cycles (DOPI mode) 9 clock cycles (Other mode) |
DVWLO0 | Device 0 select signal pull-down timing setting 0 (00): Setting prohibit 1 (01): 2.5 clock cycles (DOPI mode) 3 clock cycles (Other mode) 2 (10): 3.5 clock cycles (DOPI mode) 4 clock cycles (Other mode) 3 (11): 4.5 clock cycles (DOPI mode) 5 clock cycles (Other mode) |
CTWW1 | Device 1 single continuous write waiting cycle setting in PCLKA units |
CTW1 | Device 1 single continuous write mode setting 0 (0): Single continuous write mode is disabled for device 1 1 (1): Single continuous write mode is enabled for device 1 |
DVWCMD1 | Device 1 Command execution interval setting 0 (000): setting prohibited 1 (001): 5 clock cycles 2 (010): 7 clock cycles 3 (011): 9 clock cycles 4 (100): 11 clock cycles 5 (101): 13 clock cycles 6 (110): 15 clock cycles 7 (111): 17 clock cycles |
DVWHI1 | Device 1 select signal pull-up timing setting 0 (000): 1.5 clock cycles (DOPI mode) 2 clock cycles (Other mode) 1 (001): 2.5 clock cycles (DOPI mode) 3 clock cycles (Other mode) 2 (010): 3.5 clock cycles (DOPI mode) 4 clock cycles (Other mode) 3 (011): 4.5 clock cycles (DOPI mode) 5 clock cycles (Other mode) 4 (100): 5.5 clock cycles (DOPI mode) 6 clock cycles (Other mode) 5 (101): 6.5 clock cycles (DOPI mode) 7 clock cycles (Other mode) 6 (110): 7.5 clock cycles (DOPI mode) 8 clock cycles (Other mode) 7 (111): 8.5 clock cycles (DOPI mode) 9 clock cycles (Other mode) |
DVWLO1 | Device 1 select signal pull-down timing setting 0 (00): Setting prohibit 1 (01): 2.5 clock cycles (DOPI mode) 3 clock cycles (Other mode) 2 (10): 3.5 clock cycles (DOPI mode) 4 clock cycles (Other mode) 3 (11): 4.5 clock cycles (DOPI mode) 5 clock cycles (Other mode) |